Positive-pressure supply housing

Match positive-pressure housings to fan mounting and assembly pressure drop; confirm electrical configuration per order.

Specifications and data conditions

BSCLEAN Positive-pressure supply housing

Brochure p. 21 lists 3 housings: BSC-S220, S330 and S340. S220 lists 3680 m³/h at 20 Pa, not a universal fan rating.

Company material · p. 21

Positive-pressure supply housing · Company material 21
ParameterReported field
BSC-S220 L×W×H / fan opening1300×1588×1300 mm / 1100×1100 mm
BSC-S330 L×W×H / fan opening1910×2088×1910 mm / 1600×1100 mm
BSC-S340 L×W×H / fan opening2010×2088×2620 mm / 1600×1600 mm
BSC-S220 @20 / 30 / 40 / 50 Pa3680 / 4800 / 6000 / 7000 m³/h
Electrical enclosure fieldIP56

Installation and selection limits

Page 21 lists 380 V / 60 Hz; confirm site power. The S340 value at 20 Pa and L9 grade need verification, so do not use them as confirmed fan or efficiency specifications.

Manufacturer comparison

The table compares published fields. Dimensions, airflow, classes and test conditions differ; it does not establish performance/price rankings or direct interchangeability.

Positive-pressure supply housing / Camfil CamCube · 2026-11-20
PropertyBSCLEANCamfil CamCube
Product typeBSCLEAN: S220 / S330 / S340CamCube: ducted filter housing range
Interface exampleBSC-S220: fan opening 1100×1100 mmCamCube HF: 25 mm header frame
Supply boundaryConfirm whether fan/control are includedHousing data is not a supply-fan curve

Camfil CamCube · Official source

Sources and fields to confirm

BSCLEAN values are transcribed from supplied company material, not third-party test reports. Competitor source checked: 2026-11-20。

  • Supplied pig-farm air-filtration brochure · p. 21 · BSCLEAN
  • Camfil CamCube · 2026-11-20

Confirm 5 data groups before ordering: Fan model/curve, power frequency, L9 report, verified S340 airflow, supply list。

Discuss this product

Buyer questions

Can a housing listed as 380 V 60 Hz be connected directly to a 50 Hz farm supply?

Not from the brochure alone. Page 21 lists 380 V / 60 Hz; check motor, controls and curve and confirm a 50 Hz configuration.

What data should I send before ordering positive-pressure supply housing?

Start with 3 inputs: actual mounting dimensions, design airflow and allowed pressure drop; then confirm missing fields and model reports.

Does a filter class for positive-pressure supply housing guarantee a disease-free farm?

No. Verify at least 3 items: model efficiency, system seals and operating airflow. Filtration does not replace other biosecurity controls.