Selection guides
V-Bank, Separator or Mini-Pleat Filters: Which Fits the Installation?
Match filter construction to duty, fit and seals.

292 mm and 69 mm depths describe different constructions
BSC-YG-2 has a 592×592×292 mm frame; the mini-pleat table lists 69 mm and 90 mm depths. The difference 292−69 = 223 mm is geometric only. It does not prove equal efficiency, airflow or sealing compatibility. S1 S4
20.81 m² is media area, not the housing opening
The BSC-YG-2 catalog media area is 20.81 m²; its frame face area is 0.592×0.592 = 0.350464 m². The airflow-unit label needs verification: do not treat the source value 3400 as a confirmed m³/h rating. S1
Competitor comparison: published specifications and limits
| Comparison item | BSCLEAN BSC-YG-2 | AAF VariCel V XL |
|---|---|---|
| Frame dimensions / mm | 592×592×292 | 592×592×292 |
| Classification basis | Range lists F6–F9 and H10–H14; confirm the model | ISO 16890 ePM1/ePM10 range |
| Applicability | Airflow unit unverified; not a confirmed selection value | Match model and grade; not a direct HEPA replacement |
| Source | S1 | S2 |
This table checks published specifications, not performance or price under equal test conditions. Model ranges, duty conditions, dimension axes and classification systems differ; a single number does not establish interchangeability.
Check at least 4 requirements before replacement
Compare project class and standard, airflow and pressure drop, actual dimensions and flange, and sealing and fixing. The AAF comparison range uses ISO 16890 ePM classes. A shared 292 mm depth does not make it a HEPA replacement. Review both V-bank and mini-pleat specifications. Related specifications Related specifications
Sources and verification date
Verified 2026-11-20. Values apply to the stated models and document editions. Supply depends on confirmed specifications. Illustrative calculations state their assumptions; undisclosed data have not been invented.
- S1 Product specification table
- S2 AAF VariCel V XL, CF_407_EN_062020
- S3 BSCLEAN corresponding product specifications
- S4 Product specification table
FAQ
Can I replace a 292 mm V-bank filter with a 69 mm mini-pleat HEPA?
Not from depth alone. Check class, duty point and sealing.
Does a 20.81 m² media area mean I need that size opening?
No. The 592×592 mm frame face is approximately 0.3505 m².
If another filter is also 592×592×292 mm, is it the same HEPA?
No. ISO 16890 ePM ratings do not directly establish H14 classification.
Submit selection parameters.
Share dimensions, airflow, application and quantity for product selection and a quotation.
Get a quote