Selection guides
H13 or H14 for a Cleanroom? Match Each Filter to Its Test Report
Match HEPA grade and reports to the project.

Equal H13 and H14 dimensions do not establish equal airflow
For Camfil Absolute CE at 610×610×292 mm, CET13 lists 2535 m³/h at 250 Pa, while CET14 lists 2100 m³/h at 250 Pa. This is a model duty-point comparison, not a label-only replacement. S2
Check 2 links between each filter and its records
Match the physical filter identification to its factory test record, and the installed location to the site test record. BSC-WH-05 lists 610×610×292 mm and 2000 m³/h nominal airflow. Request clarification if a supplied report describes another size or airflow. S1
Competitor comparison: published specifications and limits
| Comparison item | BSCLEAN BSC-WH-05 | Camfil CET14-610x610x292-P-0R |
|---|---|---|
| Frame dimensions / mm | 610×610×292 | 610×610×292 |
| Rated airflow / m³/h | 2000 | 2100 |
| Initial pressure-drop condition | Range limit listed at specified velocity; not tied to this airflow | 250 Pa at 2100 m³/h |
| Source | S1 | S2 |
This table checks published specifications, not performance or price under equal test conditions. Model ranges, duty conditions, dimension axes and classification systems differ; a single number does not establish interchangeability.
List 4 acceptance requirements in the purchase documents
Specify standard and grade, test airflow and method, individual identification, and installed-system checks. An isolated catalog efficiency percentage is not an H14 commitment without class and test conditions. Confirm the supplied model and associated reports. Related specifications
Sources and verification date
Verified 2026-11-20. Values apply to the stated models and document editions. Supply depends on confirmed specifications. Illustrative calculations state their assumptions; undisclosed data have not been invented.
- S1 Product specification table
- S2 Camfil Absolute CE, 2025-10-24
- S3 BSCLEAN corresponding product specifications
FAQ
Can I upgrade H13 to H14 without checking the original fan airflow?
No. The example lists 2535 versus 2100 m³/h; check the duty point.
What information should I check on an H14 filter test report?
Check class/standard, test conditions, filter ID and installed checks.
If every HEPA has a factory report, is site leak testing still needed?
Follow project requirements; factory and installed records have different uses.
Submit selection parameters.
Share dimensions, airflow, application and quantity for product selection and a quotation.
Get a quote