Installation guides
Can Filter Photos Confirm Replacement Dimensions? A Measurement Checklist
Use measurements or drawings for production sizes.

Prepare at least 3 groups of photos
Checklist: 3 items. Provide the complete old filter and label, housing opening and clamps, and tape measurements of width/height/depth. These three groups are a document checklist, not an accuracy guarantee. Each photo must identify what is being measured and show mm readings.
Record 592×592×46 mm as 3 separate readings
BSC-ZG4-3 lists 592×592×46 mm. Record width, height and depth independently and photograph the gasket. Do not treat nominal dimensions or measurements of a deformed old frame as confirmed manufacturing sizes. S1
Competitor comparison: published specifications and limits
| Comparison item | BSCLEAN BSC-ZG4-3 | Camfil 30/30 G |
|---|---|---|
| Frame dimensions / mm | 592×592×46 | 592×592×48 |
| Initial pressure drop and stated condition | G4: 72 Pa, 2.5 m/s | 70 Pa, 3400 m³/h |
| Source | S1 | S2 |
This table checks published specifications, not performance or price under equal test conditions. Model ranges, duty conditions, dimension axes and classification systems differ; a single number does not establish interchangeability.
Keep 2 stages of confirmation
The customer confirms field measurements and conditions; the supplier confirms drawing, model and production dimensions. If only 46 mm depth is available, equal 592×592 mm face dimensions do not justify choosing a 48 mm filter. Confirm custom supply after both checks. Related specifications
Sources and verification date
Verified 2026-11-20. Values apply to the stated models and document editions. Supply depends on confirmed specifications. Illustrative calculations state their assumptions; undisclosed data have not been invented.
- S1 Product specification table
- S2 Camfil 30/30 G, Singapore specification table
- S3 BSCLEAN corresponding product specifications
FAQ
Can one front-view filter photo establish the manufacturing dimensions?
No. Supply three photo groups and measured depth and tolerances.
Should I include the gasket when measuring a custom panel filter?
Record frame and gasket separately; follow the agreed drawing definition.
If the drawing and old filter differ, can I copy the old filter directly?
No. Resolve drawing, opening and old-part differences through both checks.
Submit selection parameters.
Share dimensions, airflow, application and quantity for product selection and a quotation.
Get a quote